M/s Soorty Garments Apparel, a leading garmentsmanufacturer, producing highest quality of fashion garments for three decades. Situated in K.A.T.I Karachi, Pakistan. Soorty Garments Apparel has been manufacturing for world leading brands with high satisfaction while strictly adhering to buyers Code of Conductsand international compliance standards.
Accredidated with certifications & Audits like GOTS,Global Recycle Standard (GRS), SEDEX,SA8000,WRAP,OCS, FAIRTRADE, REACH, OKEO TEX 100, ISO 9001:2008, CTPAT, BSCI standard and BCI membership.To bring energy efficiency into this domain and to achieve sustainable energy management Soorty Garments Apparel executed Espireenergy at their premises on January 26, 2012.
Through Energy Audit energy conservation measures were identified with anannual energy saving potential of 4.537 Million PKR.An Energy Information Software was installed to enable the company to continuously monitor its energy consumption and costs.Energy Management Systemwas developed to enable the company to reduce its energy consumption further without external support. For 6 months the consultant assigned by ESPIREenergy monitored and supported implementation, documented the progress and quantified the realized costsavings.
Soorty Garments Apparelimplemented 7 improvement measures within 6 months which resulted in annual energy savings of 3.3448 Million PKR with an investment of only 1.138 Million PKR and a 4.08 months payback time.
To further improve the energy efficiency Soorty Garments Apparel has developed an Energy Policy and developed an energy team which is monitoring energy consumption and implementing energy conservation measures without external support.
ENERGY SAVING MEASURES
[implemented within first 6 months] |
ENERGY SAVING
[M-PKR/year] |
INVESTMENT
[M-PKR] |
Boiler Tuning to increase Combustion Efficiency |
0.33 |
0.06 |
Insulation of Condesnate return and Steam Lines |
0.4288 |
0.178 |
Repairing of Ineffective Insulation |
0.216 |
0.15 |
Repairing of Steam Leakages |
0.225 |
0.0 |
Condensate Recovery |
1.33 |
0.025 |
Management of Unnecessary Lights |
0.39 |
|
Repairing compressed Air Leakages |
0.425 |
|
TOTAL |
3.3448 |
0.413 |
|